1 Product introduction:
YH500 torque power indicator is specially used with YH500 series dynamic
torque sensor. The input signal is 5-15KHZ and 60 pulses/rev. It can display torque value, speed and power value on site, and the supporting software can store and display curve printing and other functions.
2 Basic technical specifications
Size: A-shaped disk mounted 160x80x170mm, including two types of LCD display and digital tube display; T-shaped desktop placement: 270x106x220mm.
The instrument with liquid crystal display, all Chinese operation interface, easy to set up, the backlight is always bright, and can be read intuitively during the day or at night. In the outdoor, the liquid crystal display can be seen more clearly than the meter displayed by the digital tube.
Instrument power supply: 220VAC Power consumption: less than 15VA
Use environment: -10℃~70℃, humidity 0~90%RH, no condensation.
Measurement resolution: The internal measurement resolution of the instrument can reach 1/1000000, the display resolution is limited by the 5-digit display digital tube, and the display resolution is 1/120000.
Measurement speed: 25 times per second
Display range:
Torque measurement: -99999~99999N.m, absolute value of display: 0~99999N.m, decimal point position can be set
Speed display: 0~99999, the decimal point position can be set
Power display: 0~99999, automatic adjustment of decimal point
Pulse input signal: various NPN, PNP, OC door output sensor signals, proximity switches, rotary encoders
Measurement frequency: Speed pulse input 0.3Hz~20KHz
Torque pulse input 5KHz~15KHz, can be extended to 1HZ~60KHZ
●Measurement refresh rate: 30 times per second, suitable for fast response occasions.
Standard transmission output
Optical isolation
2 channels of 4mA~20mA DC current output. Output resolution: 1/4000; error less than ±0.2% F.S, load capacity: less than or equal to 600Ω
External power supply
Select either ±15VDC or 24VDC, the load capacity is greater than 300mA
Standard serial communication
√Optical isolation
√ Choose either RS232 or RS485, if not specified, the default standard RS485 serial port
√ Communication protocol modbus rtu and ASCII code, choose one of the two.
●The serial port printing function is optional, and the standard serial port printer is connected to directly support Chinese type. The arrangement of Chinese type printing can be changed according to customer requirements.